HIGH-PERFORMANCE THERMOPLASTIC / PEI

PEI (ULTEM) Injection Molding Service

Plan PEI molding for equipment components that combine heat resistance, stiffness and electrical insulation. Define grade, chemical exposure and assembly requirements, then connect drying, high-temperature processing and critical-interface checks with the project.

Equipment components · Insulating interfaces · Grade and sample validation
Glass-reinforced PEI molded aerospace panels with perforations
Glass-reinforced PEI molded aerospace panels with perforations

Get a Quote for PEI Molded Parts

Identify dimensions that control fit, electrical separation or sealing, and describe temperature, load, cleaning agents and cycling. Select the PEI grade and tooling against the operating environment, quantity and validation work.

Discuss your project ↗
WHAT TO SHARE
  1. 3D CAD, drawings and critical mating/insulating interfaces
  2. Sample, initial order and ongoing production quantities
  3. Specified PEI / ULTEM grade, color and material records
  4. Temperature, loads, media and cleaning/sterilization or electrical test conditions

PEI Molding Project Options

Amber PEI ported housing for assembly review
01

Development & Interface Review

Review walls, radii, draft and critical fits before tooling. Use machined samples for geometry and assembly, and molded samples to evaluate residual stress, flow marks and shrinkage.

Molded reinforced PEI panels arranged for sample comparison
02

Mold Trials & Production Baseline

Connect resin drying, melt heat history, filling/packing and cooling. Establish the acceptable condition through samples and relevant tests before defining the production baseline.

Amber ribbed PEI housing and glass-reinforced PEI panel
03

Select the Appropriate PEI Grade

Unfilled, glass-reinforced and healthcare formulations have different records and performance limits. Select for stiffness, insulation, color, cleaning and directional behavior rather than the ULTEM name alone.

Start Your PEI Molding Project

Share drawings, quantity and thermal, electrical or cleaning requirements.

Get a PEI Molding Quote

PEI Injection Molding Project Review

Project focusReview scope
Grade and operating environmentConfirm reinforcement, color, temperature, chemical exposure and material records; do not transfer values across grades.
Drying and melt heat historyUse grade guidance for moisture and drying, reviewing high-temperature residence, changeover and material-path cleanliness.
Tooling and moldingEvaluate flow, vents, gates, packing and cooling together, focusing on heavy sections, weld lines and residual stress.
Critical interfacesDefine assembly, sealing and electrical dimensions from drawings; establish tolerances against orientation, measurement conditions and approved samples.
Samples and acceptanceSeparate appearance, dimensional, load, electrical and cleaning-cycle tests, selecting the checks required for the project.
Amber PEI housing showing rib junctions and mounting openings
DESIGN FOR MANUFACTURING

PEI Part DFM Priorities

01Walls, Radii & Stress

Use smooth section transitions and reduce sharp corners and heavy intersections. Review filling, cooling, sink and internal-void risks in thick sections.

02Gates, Flow & Interfaces

Coordinate gate location, flow direction and packing around critical fits. For reinforced grades, review fiber orientation and its effect on shrinkage, dimensions and loading.

03Venting, Draft & Release

Provide suitable vents and draft around deep ribs, long flow paths and textured faces. Apply ejection force to supported regions to limit release distortion and concentrated stress.

04Exposure & Residual Stress

Review residual stress where loads, cleaning agents or thermal cycling occur. PEI is amorphous and does not use PEEK crystallinity-control rules; validate with actual samples.

PEI Surfaces & Functional Interfaces

Define contact, assembly, cleaning and visible surfaces. Specify the exact PEI grade and color, then review material documentation against the intended use.

Close view of an as-molded amber PEI housing face
APPEARANCE DIRECTION · 01

Housing Appearance & Interface Review

Mark visible faces, openings, mounts and contact locations on the drawing. Agree on finish, surface roughness where relevant and assembly fit using molded samples of the selected PEI.

PEI Samples & Quality Verification

Record the grade, color, batch and critical dimensions with the samples. Specify component-level tests for electrical strength, chemical exposure under load and cleaning cycles, plus any device-level requirements.

Agree drawing and grade → Review mold trials and samples → Check dimensions and relevant functions → Approve the production baseline

PEI Material & Processing Data

This table uses SABIC’s Europe-region data for unreinforced ULTEM 1000. Compare candidate formulations using the matching test method, specimen and service conditions.

ULTEM 1000 Typical Properties

PropertyTypical valueMethod / conditions
Density1.27 g/cm³ISO 1183
Tensile stress at yield110 MPaISO 527; 50 mm/min
Tensile modulus3200 MPaISO 527; 1 mm/min
Flexural modulus3300 MPaISO 178; 2 mm/min
Notched Izod impact strength6 kJ/m²ISO 180/1A; +23°C; 80 × 10 × 4 mm
Heat deflection temperature, HDT/Af192°CISO 75/Af; 1.8 MPa; flatwise80 × 10 × 4 mm specimen, 64 mm span
Dielectric strength in air32.7 kV/mmASTM D149; 1.6 mm

ULTEM 1000 Injection Guidance & Shrinkage

ItemValueMethod / conditions
Drying temperature and time150°C / 4–6 hOfficial injection-molding guidance; not extrusion conditions
Maximum moisture content0.02%Maximum value in official injection-molding guidance
Melt temperature350–410°COfficial injection-molding guidance; not glass-transition or service temperature
Mold temperature135–180°COfficial injection-molding guidance; adjust and confirm for the project
Mold shrinkage: flow0.5–0.7%SABIC method; 3.2 mm laboratory coupon; see limitations below
Mold shrinkage: across flow0.5–0.7%SABIC method; 3.2 mm laboratory coupon; see limitations below

Use SABIC’s injection ranges to plan trials for the geometry, shot size and equipment. The shrinkage results come from test coupons. Study shrinkage in the intended tool and compare thermal and electrical results using the listed test methods and specimen sizes.

Reference: official SABIC ULTEM 1000 Technical data, Europe, Revision 25/06/2026; actually expanded and read October 21, 2026.

Why Choose PlasticHubs

01

Start with Function & Exposure

Review PEI grades against heat, insulation, fit and cleaning requirements, bringing key risks into quoting and development.

02

Connect Material, Tooling & Inspection

Use one project baseline for drying, molding heat history, critical dimensions and relevant tests to reduce handoff gaps.

03

Inspect Critical Assembly Interfaces

Use drawings and dimensional inspection support, including CMM, to focus on location and fit; confirm electrical, cleaning or load-related function through relevant tests.

04

Quality Systems for the Project

Use ISO 9001 / ISO 13485 quality systems and clear material, sample and inspection records to support the transition from development to ongoing production.

What Is PEI (ULTEM)?

Amber PEI molded frame and ribbed housing
Amber PEI molded frame and ribbed housing

PEI is polyetherimide, an amorphous high-performance thermoplastic. ULTEM is SABIC’s PEI resin brand. Its combination of thermal resistance, stiffness, electrical insulation and dimensional stability supports equipment parts with several functional demands.

Unfilled, glass-reinforced and healthcare formulations have different properties and records. Review chemical exposure, stress, temperature and duration together. SABIC describes ULTEM HU applications in surgical-robot wrist and arm-base components; these uses require appropriate healthcare grades and device validation, with documentation specific to the selected grade and device.

PEI Applications for Demanding Equipment

Amber PEI cylindrical housing with two side ports
01

Ported Housings & Interfaces

Ported PEI housings bring several connection features into one structure. Define fits, location and assembly acceptance around media, temperature and loading requirements, then confirm function on actual samples.

Ribbed amber PEI equipment housing
02

Ribbed Housings & Equipment Components

Ribbed housings combine mounting bosses and multiple interfaces within an equipment structure. Review walls, support and assembly space together; where insulation is required, test the selected grade and actual geometry.

Single perforated glass-reinforced PEI aerospace structural panel
03

Aerospace Structural Parts

Glass-reinforced PEI can be used for aerospace structural components. Review fiber orientation, local geometry and service loads, then validate samples against the specified grade, material documentation and project requirements.

Amber PEI enclosure with mounting bosses and front-wall openings
04

Housing & Mounting Interfaces

Review openings, internal supports and mounts against neighboring components. Mark fits, load points and measurement datums on the drawing and check assembly on molded PEI samples.

PEI Selection: Value & Limits

Evaluate the Performance Combination

Consider PEI where equipment parts need heat resistance, insulation, stiffness and stable fit together. Compare specific grades and operating conditions rather than using one maximum property value as part validation.

Account for Exposure & Manufacturing Cost

High-temperature processing, drying, tooling and validation all affect cost. For loaded chemical exposure, changing geometry or low quantities, compare material, molding and machining routes before committing to tooling.

PEI INJECTION MOLDING FAQ

PEI Injection Molding FAQ

Common questions about grades, molding, insulation and project validation.

Are PEI and ULTEM the same material?

PEI names the polymer polyetherimide; ULTEM is SABIC’s PEI resin brand, covering multiple unfilled, reinforced and specialty formulations. Specify the exact grade and color for procurement, processing and acceptance rather than the brand alone.

Are PEI melt-processing temperature, HDT and service temperature the same?

SABIC’s ULTEM 1000 injection guidance lists a 350–410°C melt range. The listed 192°C is ISO HDT under 1.8 MPa for the specified specimen. Set the service temperature separately for the part’s load, exposure and duration.

Why does PEI need drying before molding?

Moisture and contamination affect high-temperature molding and surface condition. The current Europe-region 1000 table gives injection guidance of 150°C for 4–6 hours with maximum moisture of 0.02%. Equipment, shot size, geometry or another grade may need adjustments; do not mix in extrusion conditions from the same table.

How do I choose unfilled or glass-reinforced PEI?

Select for stiffness, load, insulation, color, flow and fit. Reinforcement changes directional and shrinkage behavior, requiring grade-specific data and samples. Unreinforced 1000 values do not represent every glass-filled or healthcare formulation.

What tolerances can molded PEI parts hold?

Provide critical interfaces, datums and measurement conditions. Review geometry, grade and flow orientation when planning tooling compensation, then set tolerances from tool trials and approved samples.

Can PEI be used in medical equipment requiring repeated cleaning or sterilization?

Select the PEI grade and documentation for the required contact classification, media, temperature and cleaning or sterilization cycles. Verify any biocompatibility, implant or regulatory requirements at the finished-device level.

Is PEI compatible with every cleaner or chemical?

No. Certain chlorinated solvents, strong alkalis and concentrated acids can cause cracking or crazing under load. Check compatibility for the exact grade, concentration, temperature, contact duration and stress, using relevant tests on actual parts.

Start Your PEI Molding Project

Share drawings, quantity and thermal, insulating or cleaning requirements. Our team will review the material and manufacturing route and prepare a quote.

Get a PEI Molding Quote